The steps are as follows.
- Choose “MAINTE”
- Input “5”to User and “2222”to Password
- Choose “PARAM”
- Choose “AX.SV”
- Choose 70038,then input “2”to “S1”
- Choose “AXIS BASE”,then input the values shown on the screen
- Press the red emergency button,then turn the black button to “ON”
- Turn the red emergency button,then press the green button
The video is as follows.